Behind The Scenes Of Filling Up: Gaining Approval and Getting Started

This is Veeder-Root’s second article in their series on what actually happens when you fill up at a gas station. Read the first article here.
Veeder-Root

Most people don’t know this, but a gas station’s fuel dispenser is connected to three primary pieces of equipment that help it run a fueling transaction:

  1. Point-of-Sale System
  2. Red Jacket® ISOTROL™ 1-8 Control Box
  3. TLS-450PLUS Automatic Tank Gauge

These three pieces of equipment make up the system that manage the transaction, calculate inventory data, and facilitate the pumping of the fuel.

The Gate Keeper

When you lift the handle and start a transaction at the dispenser, nothing happens without the Point-of-Sale System approving it. This is because a POS system must authorize a sale to allow next steps to happen.  

The authorization can be done manually by an attendant at the gas station or it can be set to pre-authorization.  

Manual authorization means that someone on site must approve all transactions prior to any dispensing. If you’ve ever been at a site where an attendant must pump all gas, this is likely an instance where they’re using the manual settings. 

In instances of pre-authorization, the POS system allows a transaction to happen once the payment, usually credit or prepaid fuel card, is approved. If you have ever gone to a 24-hour site that is unattended, this is set to pre-approval. 

In either case, the Point-of-Sale System is providing a gate keeper function in the fueling transaction to make sure that only approved fuel dispenses happen. 

Sending the Signal

Now that we know the transaction is authorized, the dispenser will reset the displays and get ready to dispense fuel.  

In order to create the pressure needed in the fuel lines to dispense it, the Red Jacket® Submersible Turbine Pump will need to be activated.  

This is done when the dispenser signals the other key equipment in the process, the ISOTROL 1-8 Control Box, which notifies the TLS-450PLUS ATG. At that point the ATG sends a relay signal to the Red Jacket IQ Smart Control to start the Red Jacket STP and create pressure in the fueling lines.

Now What? 

Next week, we’re discussing how the fuel is pumped from the tank and to the dispenser, including the different modes available. 

You can find more information on every step of the process here

If you have any questions or would like to purchase Veeder-Root and Red Jacket Products, visit us online at www.johnwkennedyco.com or call us at 1.800.451.4021.

The John W. Kennedy Company appreciates your business and continued support!
JWK USA Logo

How Does it Work? Behind the Scenes of Filling Up

Veeder-Root

For most people, getting gas for their vehicle is an unavoidable, routine part of life. We do it because we have to do it.  

And while we all know how to operate a gas pump, most don’t realize that there’s a symphony of sensors and probes working together to keep the fuel flowing safely and efficiently. 

Today, we’re tackling the first piece of the fueling process, activating the dispenser.

Car Fill Up

Gas Pump vs. Fuel Dispenser 

Yes, there is a big difference between gas pumps and fuel dispensers, even though people use the words interchangeably. 

Some countries use gas pumps, which use a pumping device inside the unit to create suction. The pump pulls fuel out of the storage tank and dispenses it through the product lines and nozzles. 

In North America, we use fuel dispensers. These units work on a pressurized system using a submersible turbine pump immersed in the underground storage tanks to deliver fuel to the dispenser. 

Activating the Dispenser 

So what really happens? The customer pulls up to the dispenser, starts a transaction using a Point-of-Sale system like Passport®, removes the nozzle, and selects a grade.  

A signal is sent to the Red Jacket® ISOTROL™ 1-8 Control Box. The control box isolates signals from the dispensers, and protects against wiring shorts and phasing issues.  

The ISOTROL notifies the TLS-450PLUS Automatic Tank Gauge to activate the  Red Jacket® IQ Smart Control Box and submersible turbine pump

Now What? 

Next week, we’re breaking down the authorization process and how Veeder-Root’s integrated site solutions work together to provide a safe and seamless consumer experience at the gas station. 

You can find more information on every step of the process here.

If you have any questions or would like to purchase Veeder-Root and Red Jacket Products, visit us online at www.johnwkennedyco.com or call us at 1.800.451.4021.

 
 

The John W. Kennedy Company appreciates your business and continued support!
JWK USA Logo

A Brief Outlook: The Future of Convenience Stores

Over the past few years, convenience stores have evolved from “one-stop-shops for buying snacks and drink for a road trip” to small retail businesses that stock a wide variety of everyday products. However, it has led to an increase in competition as the market is flooded with more players. Therefore, modern c-stores need to provide excellent customer experience and value-added services to survive the hyper-competitive niche.

Continue reading