See The Latest Patriot Capital Financing Programs for Gasboy, Veeder-Root, Red Jacket & HydrX

Patriot Capital Corp

Check Out The Latest Financing Programs From Patriot Capital!

Gasboy Islander & Atlas PRIME

Exclusive Gasboy Prime Program

Get great rates and low payments!

Now through September 30, 2022, Patriot Capital is offering an exclusive financing program for Gasboy Islander Prime and Atlas Prime equipment.

Benefits of financing with Patriot Capital include:

  • 100% Project Financing
  • Deferred Payment Plan
  • Fixed Payments, Competitive Rates
  • Upgrade Multiple Sites At Once

Patriot Captital Gasboy PRIME Rates
All packages include EKOS and the fuel site module. Click here to see brochure for details and feel free to contact us today at 1.800.451.4021 or email us for more details.


Bundle Financing ProgramVeeder-Root TLS0450PLUSVeeder-Root HydrX Fuel Conditioning

Use Promo Code
PC2022

Now through September 30, 2022, Patriot Capital is offering a bundle financing program for select Veeder Root ATG, HydrX and Red Jacket equipment.

  • Eligible Products
    • The TLS-450PLUS and TLS4 Series Automatic Tank Gauges (ATGs) with available factory installed options, and probes and sensor product necessary for compliant installation except as listed below
    • HydrX Fuel Conditioning System
    • Red Jacket Submersible Turbine Pumps (STPs), including The Red Jacket, The Red Jacket AG, Red Armor®, Maxxum®, and CoreDEF™

Red Jacket Submersible Pump

  • Ineligible Products
    • TLS-350 Series ATGs, parts, and accessories
    • Mag Flex Tall Tank Probes and accessories
    • Carbon Canisters
    • Spare or replacement parts
    • Installation, shipping, and other costs are not included in the equipment financing program
  • Financing Options
    • Get 3.9% for 60 months on ATGs or HydrX financed alone.
    • Get 2.9% for up to 60 months when bundling ATGs and HydrX.
    • Get 1.9% for up to 60 months when bundling ATGs, HydrX and Red Jacket STPs.
    • For any questions on this financing program, contact us at 1.800.451.4021 or email us

Click here to see pages 3 – 6 of the program brochure for eligible part numbers.
Patriot Capital Program Bundle


Click on the logos below to find their products in our web store:


Gasboy
Veeder-Root logo
Red Jacket

And remember, if you can’t find what you are looking for, please feel free to contact us at 1.800.451.4021 or Email Us!!


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Franklin Fueling Systems: Important Product Updates

FFS EVO

EVO™ SERIES SOFTWARE UPGRADES NOW AVAILABLE VIA EMAIL

Effective immediately, all EVO™ Series Automatic Tank Gauge (ATG) internal software field upgrades will be delivered via email in lieu of physical USB thumb drives. In order to speed delivery and comply with new security standards, field upgrades will be provided as a download link sent via email upon purchase. This applies to all EVO™ Series ATGs.

A list of available software upgrades follows below:


Internal Software / Field Upgrades

Model Description
TS-TT (T) Statistical Continuous Automatic Leak Detection, 24 hour continuous tank testing software
TS-TRAC (R) Tank inventory reconciliation and autocalibration
TS-TRAC-F (F) Reconciliation/autocalibration and flow rate monitoring software
TS-FLOW Flow rate monitoring
TS-ELLD (L) Electronic line leak detection
TS-ELLD-G (G) Electronic line leak detection for generator applications
TS-CON (C) Enhanced logic conditions including value, counter, value compare, and latch
TS-SCM (S) Secondary containment monitoring

MODEL NUMBER UPDATE: ANALOG PROBES

Please be aware that the model numbers for several Analog Inventory & Leak Detection Probes (LL2 models) have been updated. There are no functional changes in the operation of any of these probes. There are no changes in pricing. Please update your ordering information using the cross reference provided below.

Analog Inventory & Leak Detection Probes

FFS Legacy Probe
Legacy Model New Model Description
TSP-LL2-69 TSP-LL2-69 CN 69” analog leak detection probe
TSP-LL2-69-I TSP-LL2-69-I CN 69” analog inventory probe
TSP-LL2-81 TSP-LL2-81 CN 81” analog leak detection probe
TSP-LL2-81-I TSP-LL2-81-I CN 81” analog inventory probe
TSP-LL2-89 TSP-LL2-89 CN 89” analog leak detection probe
TSP-LL2-89-I TSP-LL2-89-I CN 89” analog inventory probe
TSP-LL2-101 TSP-LL2-101 CN 101” analog leak detection probe
TSP-LL2-101-I TSP-LL2-101-I CN 101” analog inventory probe
TSP-LL2-107 TSP-LL2-107 CN 107” analog leak detection probe
TSP-LL2-113 TSP-LL2-113 CN 113” analog leak detection probe
TSP-LL2-113-I TSP-LL2-113-I CN 113” analog inventory probe
TSP-LL2-125 TSP-LL2-125 CN 125” analog leak detection probe
TSP-LL2-125-I TSP-LL2-125-I CN 125” analog inventory probe
TSP-LL2-158-I No Change 158” analog inventory probe
TSP-LL2-161-I No Change 161” analog inventory probe
TSP-LL2-167-I No Change 167” analog inventory probe
TSP-LL2-168-I No Change 168’ analog inventory probe
TSP-LL2-170-I No Change 170” analog inventory probe
TSP-LL2-173-I No Change 173” analog inventory probe
TSP-LL2-179-I No Change 179” analog inventory probe
TSP-LL2-185-I No Change 185” analog inventory probe
TSP-LL2-197-I No Change 197” analog inventory probe
TSP-LL2-209-I No Change 209” analog inventory probe
TSP-LL2-215-I No Change 215” analog inventory probe

Be sure to check out Franklin Fueling Systems Complete Line-up Of Products in Our Web Store!

And if you can’t find it, call us at 1.800.238.1225 or email us and we will be happy to help!!

FFS APT FFS CableTight FFS EBW
Franklin Fueling Systems EVO-Incon Logo FFS FE Petro FFS Flex-Ing
FFS Healy FFS Power Integrity FFS UPP

Don’t hesitate to contact us If you have any questions about Franklin Fueling Systems products  or would like to receive a quote. Contact us at 1.800.238.1225 or Email Us with any further questions or inquiries.


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Veeder-Root Technical Support Notification: Probe & Sensor Wiring

Probe & Sensor Wiring

Introduction

Veeder-Root has specific requirements for all Automatic Tank Gauge (ATG), probe, sensor and Pressurized Line Leak Detection (PLLD) transducer wiring – this is to maintain intrinsic safety as well as reduce electrical noise interference. This notification will provide a brief introduction into Veeder-Root’s probe and sensor wiring requirements. This should be used in conjunction with local, state and federal electrical codes.


Basic Wiring & Installation Requirements

The following are Veeder-Root’s field wiring requirements:

  • All probes and sensors must use two-wire shielded cable.*
  • Use a single continuous length of shielded cable with no splices to ensure optimum signal strength.
  • All shielded cable runs must be less than 1000 feet.
  • An epoxy pack must be used for all wiring splices in the field.
  • Weatherproof junction boxes are required for all conduit runs to the monitoring locations (e.g., STP sump or dispenser pan).
  • All shields must be grounded at the console, cut-off in the field.
  • When exiting the console, shielded cable must be run through rigid conduit.
  • Shielded cable should be rated between 14 to 18 AWG stranded copper wire and must be rated less than 100 picofarads per foot.**

* When installing a three-wire sensor, use a three-wire shielded cable.
** Refer to the TLS-450PLUS Site Prep and Installation Manual (577014-073) for wiring examples.


ATG Installation & Grounding

  • All three divider plates must be left in place in-between any of the four slots in the TLS-450PLUS console or the TLS-XB Expansion Box.
  • The divider plates and empty slot covers cannot be modified in any way. This includes drilling holes or cutting the plates.

Note: Removing or modifying the divider plate can lead to electrical noise interference issues and violates UL/cUL and other licensing bodies.

  • Four-conductor or more shielded cable cannot be used with Veeder-Root probes or sensors. Two wires cannot be connected to a sensor while the other two wires are connected to another device, even if the two devices are installed in the same sump.
  • Confirm the console has two isolated grounds.

To test the grounds, disconnect these two cables from the console. Place the leads of the ohmmeter on each grounding wiring and confirm it reads less than 1 ohm of resistance. If it reads more than 1 ohm of resistance, then the console has bad grounding, which could be a cause of an electrical noise interference issue.


Installation Review

This example shows a clean installation.

✅ One pair of two-conductor shielded cable is used per device.

✅ All shields are grounded at the console.

✅ All shielded cable is run through a rigid conduit.


This example shows an incorrect installation.

The field wiring does not meet Veeder-Root, UL/cUL and other licensing bodies’ wiring requirements. This site is using four-conductor shielded cable. (Shields are not shown).
As mentioned before, two-conductor shielded cable is required for all probes and sensors.