Veeder-Root: TLS4 Series Security Settings

TLS4 Series

Technical Support Notification

TLS4 Series Security Settings

Overview

The TLS4 Series consoles come with security features allowing for greater protection and control of access to the Automatic Tank Gauge. Features such as configurable user access and segmented network ports help ensure both network and front-panel security.

This update covers:

  • User and Roles Admin
    • Create User Accounts
    • Custom Roles
  • System Security
    • Front Panel Security
    • Serial Command Port (TCP/IP Interface)
    • SSH Port
    • Serial Command Over SSH
    • HTTPS Port
    • User Admin Via Web
  • Router and Network Switch

User & Roles Admin

Create User Accounts & Custom RolesCreate User Accounts

All TLS4 Series consoles come preconfigured with three roles: Administrator, Operator and Regulator. Additional custom roles can be programmed.

Menu –> System Administration –> Roles Admin

Administrator: This role gives full access to the console – including the ability to create new roles and users.

Operator: This role allows the user to view and generate reports and perform certain manual functions, such as starting a manual line or tank test.

Regulator: This role allows the user to print and view console reports.

Note: Users assigned to the Regulator role cannot be deleted.

To add a Custom role, select Actions –> Add New Role

The Custom role allows each individual screen to be viewable, editable or not accessible. For example, in Setup under the Automatic Events section, each option can be customized:

Veeder-Root strongly recommends creating an Administrator account with a unique password. This will disable the default username and password.

Note: When using the Plus View or Remote View apps, the same login credentials are used.


Security

System SecuritySecurity Settings

The TLS4 Series consoles have optional security features to enhance protection in addition to front panel security that requires a username and password, when enabled.

Front Panel Security: When disabled, all users can access all screens with no password required. When enabled, users must login with a password to gain access to the screens they’re allowed to view.

Serial Command Port (TCP/IP Interface): When disabled, the console will not accept any serial commands sent through a telnet session.

Note: This will not block all traffic on the TCP/IP port. It will only block serial commands.

SSH Port: When disabled, all traffic on the SSH port will be blocked.

Serial Command Over SSH: For the SSH Public Keys feature to work, this port and the SSH port must be enabled. By default, this port is disabled.

HTTPS Port (Web Access): When disabled, all traffic on the HTTPS port will be blocked. This will prevent access to the web portal, and the Plus View and Remote View apps.

User Admin via Web: When disabled, the System Administration screens will be blocked from the web portal – access to these two screens will only be available on the console’s front panel.

Router or Network Switch

Most routers or network switches have additional features allowing ports to be enabled or disabled. Contact device manufacturers or internet service providers (ISPs) for more information.


Download the TLS4 TSN HereVeeder-Root TLS4 TSN


LOOKING FOR VEEDER-ROOT SYSTEMS & PARTS?

Well look no further – click on the Veeder-Root logo below to visit our web store, where we have hundreds of the most popular Veeder-Root items ready to buy in our webstore and if you can’t find it there, please contact us!
Veeder-Root logo


If you have any questions about TLS4 Series or would like to receive a quote for TLS4 Series or any other Veeder-Root system and/or parts , please feel free to contact us at 1-800-451-4021 or Email Us with any further questions or inquiries.


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Software Release Version 10.B

Veeder-Root TLS-450PLUSSoftware Release Version 10.B
TLS-450PLUS and TLS4 Series Consoles

Purpose

This document announces the release of version 10.B software for the TLS-450PLUS and TLS4 series consoles.

Performance Enhancements

Intelligent Pump Control Reports
• Advanced Diagnostics Reporting for Intelligent Pump Control (IPC) for Red Jacket STPs. IPC collects statistical data from pump controllers that includes daily run time, start count, number of help requests, faults, fault counts, time in a fault condition, min/max/average (running) voltage and amperage.

Ongoing Improvements
• Version 10.B includes miscellaneous bug fixes and updates.

Software Upgrade Kit – TLS-450PLUS, TLS4 Series Consoles

Software upgrades are always free to download on the Veeder-Root website at veeder.com/us/software-downloads.

Software upgrades can also be ordered on a USB Flash drive at no charge by ordering the software kit part number
in the table below:

Part Number Description List Price
0330020744 TLS450PLUS, TLS4 Series Operating Software Upgrade No Charge

Documentation

Manual information is available at veeder.com/us/technical-document-library.


LOOKING FOR VEEDER-ROOT SYSTEMS & PARTS?

Well look no further – click on the Veeder-Root logo below to visit our web store, where we have hundreds of the most popular Veeder-Root items ready to buy in our webstore and if you can’t find it there, please contact us!
Veeder-Root logo


If you have any questions about this software release notification or would like to receive a quote for Veeder-Root systems and/or parts , please feel free to contact us at 1-800-451-4021 or Email Us with any further questions or inquiries.


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Mag Plus In-Tank Probe Installation Kits EOL Notification

Mag Plus In-Tank Probe Installation Kits EOLMag Plus In-Tank Probe Installation Kits EOL

VeederRoot is committed to providing the highest quality products and services to our customers. As the world leader in the development of fueling system technology, we view product End of Life (EOL) as part of the natural cycle that drives technology evolution.
Therefore, effective immediately we are obsoleting:
All 3” float kits
2” float kits with cable lengths 10’ and 20’
4” float kits with cable lengths 10’ and 20’
If a 10’ or 20’ probe cable is required, the cable may be purchased as a spare part.
Due to lower demand of these installation kits, it is no longer feasible to support these going forward.


CLICK HERE to read the full Mag Plus In-Tank Probe Installation Kit EOL Notification


Veeder-Root Global Market
Transition Details

For customers currently using a 3” float kit, we recommend transitioning to a 2” float kit which is compatible with the Mag Plus Probe. Mag Plus Installation Kits will come standard with a 5’ cable. If a longer cable is required, it must be purchased separately.


CLICK HERE to read the full Mag Plus In-Tank Probe Installation Kit EOL Notification


LOOKING FOR VEEDER-ROOT SYSTEMS & PARTS?

Well look no further – click on the Veeder-Root logo below to visit our web store, where we have hundreds of the most popular Veeder-Root items ready to buy in our webstore and if you can’t find it there, please contact us!
Veeder-Root logo


If you have any questions about this EOL notification or would like to receive a quote for Veeder-Root systems and/or parts , please feel free to contact us at 1-800-451-4021 or Email Us with any further questions or inquiries.


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Pneumercator January 2022 Technical Certification Training Webinar Invitation

2-Day Online Technical Certification Training

When:  January 11 – 12,2022 (2-day online course)
Time:  9AM to 4:30PM Eastern (8AM to 3:30PM Central, 7AM to 2:30PM Mountain, 6AM to 1:30PM Pacific)

Cost: $275.00 per technician. DO NOT EMAIL CREDIT CARD INFO.

To Register: Call 1.631.293.8450 or email robyn@pneumercator.comDO NOT EMAIL CREDIT CARD INFO.

NOTE: You will be provided with the webinar link once you have registered. Certification is valid for 2 years


Pneumercator TMS4000Course Overview: This class offers technicians the opportunity to obtain or renew factory certification necessary to perform installation, startup, repair, and maintenance of the select Pneumercator products listed below.


Recommended Experience/Education: All attendees should have some prior experience with the installation and
maintenance of electronic tank gauging and leak detection systems, including general knowledge of NEC/NFPA electrical code requirements, and more specifically, hazardous location classified installation and wiring requirements and safety procedures.

Pneumercator TMS2000

Required Materials: A computer with internet access. Webcam optional. Dial up voice support provided via telephone number upon signing into webinar. Groups may share a computer but a larger screen (i.e. projector, large TV, etc.) is recommended.

Materials Provided:
Training Presentation via internet link.

TMS Communicator via internet link.

Certification: Renewal required every 2 years.


Pneumercator LC1000AProducts Covered:

  • LC1000-A Series Non-Discriminating Leak and/or Pt. Level Sensing system.
  • LC2000 Series Discriminating/Non- Discriminating Leak/Pt. Level Sensing system.
  • PC1000 Series pump controller.
  • TMS Series Automatic Tank Management Systems.
      • TMS3000: Multi-Tank Gauging System, 12 Tanks and 40 Leak/Pt. Level Sensors.
      • TMS2000: Two Tank Gauging System, 8 Leak/Pt. Level Sensors.
      • TMS2000W (Wireless): Multi-Tank Gauging System, 12 Tanks and 40 Leak/Pt. Level Sensors.
      • TMS1000: Single-Tank Gauging System, Non-Hazardous Applications, 4 Leak/Pt. Level Sensors.
      • TMS2000A1x: 4-20 mA Input Tank Gauging System, 4 Tanks and 4 Leak/Pt. Level Sensors.

    Pneumercator Probe

    • TMS2000A2x: Resistive Input Tank Gauging System, 4 Tanks and 4 Leak/Pt. Level Sensors.
    • TMS4000: Multi-Tank Gauging System w/Touch Screen, 48 Tanks and 48 Leak/Pt. Level Sensors.
    • TMS4000W (Wireless): Multi-Tank Gauging Sys. w/Touch Screen, 32 Tanks and 128 Leak/Pt. Level Sensors. 
  • Magnetostrictive Probes
  • Sensors
    • Point Level Sensors
      • LS600 Series (includes LS600, LS600W, LS600M, LS600F4, and LS600X)
    • Leak Sensors
      • LS600LD
      • LS610
      • RSU800
      • Pneumercator ES825 SensorES825 (Non-Discriminating and Discriminating)
      • HS100ND
      • HS100D
    • Line Leak Sensors
      • LLP203
  • TMS Communicator
    • TMSComm
    • Autopolling
    • TMS Network Configuration
  • Special Applications using flexible probes: Bulk Storage, Low Ceiling clearance, Chemicals.


See the Pneumercator Technical Certification Training Class Invitation here.


Looking for Pneumercator systems and parts? Pneumercator Liquid Level Control SystemsCheck out our web store!

And if you can’t find what you are looking for, please call us at 1.800.238.1225 or Email Us with any further questions or to place an order!


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Pneumercator Technical Certification Training Webinar Invitation

2-Day Online Technical Certification Training

When:  December 7-8, 2021 (2-day online course)
Time:  9AM to 4:30PM Eastern (8AM to 3:30PM Central, 7AM to 2:30PM Mountain, 6AM to 1:30PM Pacific)

Cost: $200.00 per technician. DO NOT EMAIL CREDIT CARD INFO.

To Register: Call 1.631.293.8450 or email training@pneumercator.comDO NOT EMAIL CREDIT CARD INFO.

NOTE: You will be provided with the webinar link once you have registered. Certification is valid for 2 years


Pneumercator TMS4000Course Overview: This class offers technicians the opportunity to obtain or renew factory certification necessary to perform installation, startup, repair, and maintenance of the select Pneumercator products listed below.


Recommended Experience/Education: All attendees should have some prior experience with the installation and
maintenance of electronic tank gauging and leak detection systems, including general knowledge of NEC/NFPA electrical code requirements, and more specifically, hazardous location classified installation and wiring requirements and safety procedures.

Pneumercator TMS2000

Required Materials: A computer with internet access. Webcam optional. Dial up voice support provided via telephone number upon signing into webinar. Groups may share a computer but a larger screen (i.e. projector, large TV, etc.) is recommended.

Materials Provided:
Training Presentation via internet link.

TMS Communicator via internet link.

Certification: Renewal required every 2 years.


Pneumercator LC1000AProducts Covered:

  • LC1000-A Series Non-Discriminating Leak and/or Pt. Level Sensing system.
  • LC2000 Series Discriminating/Non- Discriminating Leak/Pt. Level Sensing system.
  • PC1000 Series pump controller.
  • TMS Series Automatic Tank Management Systems.
      • TMS3000: Multi-Tank Gauging System, 12 Tanks and 40 Leak/Pt. Level Sensors.
      • TMS2000: Two Tank Gauging System, 8 Leak/Pt. Level Sensors.
      • TMS2000W (Wireless): Multi-Tank Gauging System, 12 Tanks and 40 Leak/Pt. Level Sensors.
      • TMS1000: Single-Tank Gauging System, Non-Hazardous Applications, 4 Leak/Pt. Level Sensors.
      • TMS2000A1x: 4-20 mA Input Tank Gauging System, 4 Tanks and 4 Leak/Pt. Level Sensors.

    Pneumercator Probe

    • TMS2000A2x: Resistive Input Tank Gauging System, 4 Tanks and 4 Leak/Pt. Level Sensors.
    • TMS4000: Multi-Tank Gauging System w/Touch Screen, 48 Tanks and 48 Leak/Pt. Level Sensors.
    • TMS4000W (Wireless): Multi-Tank Gauging Sys. w/Touch Screen, 32 Tanks and 128 Leak/Pt. Level Sensors. 
  • Magnetostrictive Probes
  • Sensors
    • Point Level Sensors
      • LS600 Series (includes LS600, LS600W, LS600M, LS600F4, and LS600X)
    • Leak Sensors
      • LS600LD
      • LS610
      • RSU800
      • Pneumercator ES825 SensorES825 (Non-Discriminating and Discriminating)
      • HS100ND
      • HS100D
    • Line Leak Sensors
      • LLP203
  • TMS Communicator
    • TMSComm
    • Autopolling
    • TMS Network Configuration
  • Special Applications using flexible probes: Bulk Storage, Low Ceiling clearance, Chemicals.

See the Pneumercator Technical Certification Training Class Invitation here.


Looking for Pneumercator systems and parts? Pneumercator Liquid Level Control SystemsCheck out our web store!

And if you can’t find what you are looking for, please call us at 1.800.238.1225 or Email Us with any further questions or to place an order!


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Omntec Proteus FREE Web-based Training Course

Omntec Proteus ATG

JOIN OMNTEC FOR ONLINE ASC TRAINING ON 12/13/21 @ 11 AM EST

OMNTEC’s FREE ASC training is a web-based course including an exam that can be completed at your own pace. The training presentation is live and hosted through Zoom. The course is roughly 2.5 hours long.

Once you register for December’s session, you will receive an email with links to documents you can reference during the training session and the certification.

The Zoom meeting link will be sent out the Friday before the training session. Upon completion of both the training and exam, you will be provided a certificate and a wallet card that will be emailed directly to you.

REGISTER HERE

Omntec Proteus ATG

Omntec logo
You can find Omntec products in our web store
John W Kennedy Company | Omntec SBI
Use our Proteus Shop By Image feature

The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

OMNTEC: PROTEUS Serial Interface Manual Update

Omntec Proteus Serial Interface ManualOmntec Has Update Their PROTEUS Serial Interface Manual

CLICK HERE to Download the Manual!

Looking for other great Omntec solutions, equipment or replacement parts?

Look no further than JohnWKennedyCo.com!  And if you can’t find what you are looking for, no worries!  Just contact us as we have access to Omntec’s complete line of products.

Omntec JWK Shop By ImageCheck out JWK’s very own Shop By Image feature of the Omntec Proteus K4 Basics to buy directly from the image! Omntec JWK Shop By ImageLooking for Omntec products and parts? Look no further and buy online today from JWK!

Watch for Omntec’s new ECC Series product announcement coming soon!


Feel free to contact us at please call us at 1.800.238.1225 or Email Us with any further questions or to place an order!


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Franklin Fueling Systems EVO™ 600 & EVO™ 6000 ATG FIRMWARE UPGRADE

Evo Firmware UpgradeFranklin Fueling Systems has just released new firmware for EVO™ 600 and EVO™ 6000 Automatic Tank Gauges.


Here are a few of the improvements included with this firmware upgrade:

  • Configure conditions using Water Separator Levels.
  • Generate Line Leak reports using One Touch Buttons.
  • Increased the number of configurable sensors.
Upgrade Instructions
Upgrade Instructions
Upgrade Instructions
Release Notes
FFS EVO 600 ATGEVO™ 600 & EVO™ 6000
Current Firmware Version: 3.10.1
Download Firmware

Looking for EVO automatic tank gauging systems, components, accessories and parts?
Check out our EVO line of products in our web store:

FFS EVO ATGs

If you have any questions about Franklin Fueling Systems EVO ATGs  or would like to receive a quote, please feel free to contact us at 1-800-451-4021 or Email Us with any further questions or inquiries.


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Is Water In Your Fuel System Causing Corrosion?

Veeder-Root logoTake the Veeder-Root our quick quiz to assess the factors affecting your risk for underground storage tank corrosion.

Is water in your fuel system causing corrosion?
TAKE THE QUIZ NOW!


Find Veeder-Root products in our Web Store!Veeder-Root TLS-450PLUS

Have any questions or would like to receive a quote for HydrX? Can’t find the Veeder-Root you are looking for?  No problem! Please feel free to contact us at 1-800-451-4021 or Email Us with any further questions or inquiries.


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Franklin Fueling Systems EVO: NEVER STOP EVOLVING

EVO - Franklin Fueling Systems |John W Kennedy Company

EVO™ 200 & EVO™ 400: Automatic Tank Gauges

EVO™ 200 & EVO™ 400 Automatic Tank Gauges (ATGs) provide highly accurate inventory management and containment monitoring for small to mid-size fuel systems.


EVO™ 200 & EVO™ 400 ATGs

NEVER STOP EVOLVING

We are driven by our pursuit to innovate, simplify, secure, and connect every station owner to their fuel management system. EVO™ 200 & EVO™ 400 ATGs feature simple setup and operation, remote connectivity, and advanced security features to protect your fuel system while keeping you directly connected to vital site data whenever, and wherever.

Highly Capable

EVO™ 200 & EVO™ 400 allow you to make informed, data-driven inventory management decisions with features like, inventory monitoring, tank testing, and containment compliance monitoring.

Simple Interface

A full-color 7” LCD touchscreen serves up one of the most intuitive user interfaces available with simplified user features you won’t find anywhere else.

Secure Data

EVO™ Series ATGs keep your site in compliance and protected from security threats with customizable user roles, user activity tracking, and up to 3-years of data back-up to protect against power outages or other system interruptions.

TECHNICAL ADVANTAGES


Input Capacity Input CapacityEVO™ 200 can support any combination of up to 6 sensors and probes, while the EVO™ 400 can support any combination of up to 14 sensors and probes. Turbine Pump Interface Turbine Pump InterfaceEnhanced remote pump monitoring and control including pump-in-water automation, clogged intake escalation, tank leveling, and tank priority.
Remote Communication Remote CommunicationThe FFS PRO™ Connect web interface allows users to securely connect directly to an EVO™ Series ATG from any web enabled device. Inventory Reconciliation Inventory ReconciliationInventory Reconciliation is an automated leak detection function that analyzes tank volume, deliveries, and sales data to detect fuel loss or gains with a high level of accuracy.
Tank Autocalibration Tank AutocalibrationEliminate discrepancies in delivery reporting and daily reconciliations caused by inaccurate tank information programmed into the ATG with this function that automatically generates a highly accurate tank strapping chart. NEW: Flow Rate Monitoring NEW: Flow Rate MonitoringDetect and react to potential slow flow issues with automated daily reporting and alarms, helping to improve flow rates and dispenser throughput.
SIMPLICITY & VISIBILITY |John W Kennedy Company

SIMPLICITY & VISIBILITY

A full-color 7” LCD touchscreen serves up one of the most intuitive user interfaces available with simplified user features you won’t find anywhere else. You choose your home screen, you program your product colors, and you choose what shows up on your Favorites screen. Customize the interface to meet your business needs the way you operate.

Icon-Based Design

Icon-Based Design

Designed to be understood easily and operated intuitively. It’s simple to operate for new users and can reduce the amount of training required to operate.

One Touch Buttons

One Touch Buttons

You can customize these home screen buttons to automate and carry out anything from complex, multi-function processes to simple daily delivery report generation – all with the touch of a single button.

Quick Jump Menu

Quick Jump Menu

Navigate quickly from application to application with ease. This time-saving menu makes the interface’s structure extremely shallow, simple to navigate, and reduces the amount of steps it takes to accomplish tasks.

SYSTEM SECURITY

SYSTEM SECURITY

EVO™ Series ATGs help keep sites in compliance while providing marketers with the highest level protection from the security threats facing our industry.

User RolesCustomizable user roles and log-in security protect against unwanted access and track user activity. Data Back-UpStores up to 3-years of data to provide back up security from power outages or other system interruptions. Secure WiFiOptional WiFi allows secure and protected onsite viewing of inventory levels for fuel delivery drivers.
REMOTE CONNECTIVITY

REMOTE CONNECTIVITY

The FFS PRO® Connect web interface allows you to securely connect directly to your EVO™ Series ATG from any web enabled device. It automatically scales for tablets and smart phones, meaning no app to download.

INTERACTIVE DEMO

FFS PRO® Connect FFS PRO® CONNECTFFS PRO® Connect displays real-time data allowing precise delivery scheduling and efficient site management. It also provide immediate notification of alarms so quick corrective actions can be taken.
Centralized ControlProvides centralized control of all compliance information – such as tank testing data and leak detection sensor status.
ReportingA wide variety of reports can be custom-scheduled, displayed, printed, or emailed at specific times.
Simplified SetupSimplifies setup and programming with the ability to download specific sections or the entire configuration from one ATG to another.
TURBINE PUMP INTERFACE

TURBINE PUMP INTERFACE

Turbine Pump Interface is a powerful tool that creates a network between your Submersible Turbine Pump (STP) controllers and EVO™ Series ATGs. Through TPI, the tank gauge can be programmed to respond to faults in the submersible pumping system and react with intelligence that pump controllers alone cannot.

SEE TPI IN ACTION

Pump In Water AutomationWhen the water level in a tank approaches the pump intake, the tank gauge will enter alarm mode and automatically shut down the pump, protecting the system and consumers from water being pumped from that tank. Leveling & Priority ModesWhen managing two storage tanks of the same product ‘Leveling Mode’ can keep both tanks at the same percentage full without the use of a syphon bar between the two tanks. Remote Pump InteractionBy networking the intelligent controllers to the fuel management system via TPI, a technician can remotely connect to the site to review the logged event history and view the status.
FLOW RATE MONITORING

FLOW RATE MONITORING

Improve dispenser throughput and maintain fast flow rates with the ability to detect and react to potential slow flow issues before they impact business with Flow Rate Monitoring. Available as a software option on new EVO™ Series ATGs or as a field upgrade option, Flow Rate Monitoring delivers ongoing flow rate performance data, flow rates for each fueling point, and provides a notification if transactions dip below a user-defined set point.

FLOW RATE MONITORING SELECTION GUIDE

Know Your FlowMonitor for and ensure fast and consistent dispenser throughput with daily reports and alarm notifications regarding flow rate performance. Performance MonitoringSales and dispensing duration data are automatically reconciled to help you better understand the flow performance of every fueling point. Proactive MaintenanceOften, slow flow rates can indicate that a dispenser filter needs to be changed. Be proactive in calling for maintenance, getting dispensers back to peak performance sooner.
FIND THE RIGHT EVO™ SERIES ATG FOR YOUR SITE

FIND THE RIGHT EVO™ SERIES ATG FOR YOUR SITE

The EVO™ Series family of ATGs offers four different options with right-sized features to meet the requirements of your specific application, size, and compliance needs. Which ATG is right for your application?

ATG SELECTION GUIDE

Components

Components
1. Cover 2. LCD touch screen 3. LED indicators 4. Anunciator (audible alarm)
5. RS-485 6. Mini USB port 7. Ethernet / USB port 8. RS-232
9. Knockouts 10. Mounting holes 11. Flip up panel (touch screen) 12. Termination blocks
13. Main board

With pre-configured hardware and customizable software options, these ATGs provide straightforward tank level monitoring and compliance. Their simple setup and operation, remote connectivity, and advanced security features protect your fuel system while keeping you directly connected to vital site data whenever, and wherever.
  • Provides inventory monitoring, static (included feature) and continuous tank testing (optional feature), tank autocalibration, inventory reconciliation, flow rate monitoring and containment compliance monitoring.
  • Both ATGs feature the capability to interface with probes and sensors in any combination up to 6 (EVO™ 200) or 14 (EVO™ 400).
  • Customizable user roles and log-in security features protect against unwanted access while keeping track of user activity within your system.
  • Streamlined setup and programming includes hardware auto-detection and wiring confirmation, multipoint tank charting, network printer auto-detection, and the ability to download and upload entire programming profiles from one ATG to another.
  • Available with optional 24-hour Statistical Continuous Automatic Leak Detection (SCALD) and Turbine Pump Interface (TPI) capability for enhanced and automated submersible turbine pump control.
  • Web interface allows you to directly connect to your ATG via FFS PRO® Connect from any web-enabled device.
  • Optional Wifi allows secure and protected on-site viewing of inventory levels for fuel delivery drivers.
  • Intuitive full-color 7” (17.78 cm) touch screen interface provides simplified on-site access features including:
    • Six available One Touch buttons that are custom programmed to carry out common automated tasks with a single tap.
    • Quick Jump menu allows you to quickly maneuver from application to application using a single button.
    • Programmable product colors.

General

• Maximum tanks monitored: 6 (EVO™ 200) / 14 (EVO™ 400)

• Maximum sensor input capacity: 6 (EVO™ 200) / 14 (EVO™ 400)

• Total # of inputs: 6 (EVO™ 200) / 14 (EVO™ 400)

• Dry contact input channels: 2

• Relay output channels: 2

• Connectivity: Ethernet, RS-232, RS-485, standard USB, mini USB, and Wifi (optional)

• Display type: 7” (17.78 cm) color LCD touch screen

• Printer support: External (network or USB)

• Alarm: Internal audible alarm

• LEDs: Alarm, warning, and power

• Tank chart correction points: 7,500

• Applicable liquids: Petroleum, chemicals, and waste oil

• Level units: Inches, centimeters, and millimeters

• Volume units: gallons or liters (mass with density option)

• Power requirements: 110 to 240 VAC, 50/60 hz, 1.0 Amps max.

• Operating temperature: 32° to 104 °F (0° to 40 °C)

• Humidity: 0-90% non-condensing

• Dimensions: Height: 8” (205mm), Width:13 ¾” (350mm), Depth: 3¼” (83mm)

Capabilities

• High/low product, water, and temperature alarm set points

• Inventory reconciliation / tank auto-calibration / flow rate monitoring (optional)

• Density, mass, and phase separation measurement

• Email and SMS notifications

• Back-up generator monitoring

• MODBUS™ support

Approvals/Certifications

UL, cUL, ATEX, IECEx

• Third party certification of leak detection capabilities


FFS APT FFS CableTight FFS EBW
FFS EVO FFS FE Petro FFS Flex-Ing
FFS Healy FFS Incon FFS UPP

If you have any questions about Franklin Fueling Systems EVO ATGs  or would like to receive a quote, please feel free to contact us at 1-800-451-4021 or Email Us with any further questions or inquiries.


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo