Franklin Fueling Systems Submersible Pumping Systems 60hz Pump Selection Guide

Franlin Fueling Systems FE Petro STPFranklin Fueling Systems FE Petro STPIf you’ve ever needed quick assistance selecting a submersible pumping system, look no further than
Franklin Fueling Systems’
60 Hz Pump Selection Guide

 

 

While the 60 Hz Pump Selection Guide doesn’t cover every conceivable configuration you may run into, it covers 5 major system factors to help you determine the right pump for your application.

  1. Find the system layout that best represents your application using the dispenser count, pipework diameter, and visual pipework layout guide.
  2. Review the common system characteristics.
  3. Select the appropriate pump to achieve optimal flow rates for the number of nozzles operating simultaneously (recommendation highlighted in green).
  4. Review the pump recommendation explanation.
  5. Choose the specific pump model from options including base, bio-fuel compatible, and advanced protection models.

 

 

Typical systems in the guide cover configurations from 4 dispensers using 1-3/4″ piping, up to 8 dispensers using 2″ piping in both parallel and series layouts.

Piping Configurations

 

The guide also covers whether you need to consider variable speed, biofuel compatibility and other suggested options.  Be sure to check out the 60 Hz Pump Selection Guide from Franklin Fueling Systems if you are looking for some guidance on submersible pumping systems!

 

And do not hesitate to contact us at 1.800.451.4021 for additional information and any further questions you may have!

FranklinFueling.com
FFSPRO Site Builder FFSPRO Advantage FFSPRO Verify FFSPRO University

Be sure to check out our ever-expanding product offerings and great deals from Franklin Fueling’s many brands found in our webstore.

FFS APT FFS CableTight FFS EBW
FFS EVO FFS FE Petro FFS Flex-Ing
FFS Healy FFS Incon FFS UPP

The John W. Kennedy Company appreciates your business and continued support!

 

JWK USA Logo

The Red Armor STP for Corrosive Environments

Red Jacket Red Armor STP for Corrosive EnvironmentsBuilt To Survive!

The use of Ultra Low Sulfur Diesel and an increase in availability of ethanol blends are contributing to the corrosion of in-sump and in-tank equipment. With a special coating and stainless steel parts the Red Armor series of Submersible Turbine Pump (STP) combats corrosive environments ensuring easy maintenance for the life of the pump.

 

LEARN ABOUT COMBATING CORROSIONRed Jacket Red Armor STP

 

 

 

THE RED ARMOR STP: The ultimate survivor in your fueling infrastructure.

 

    • Specialty coating on all cast surfaces that withstands acetic acid exposure to prevent pitting and deterioration over time
    • Stainless Steel construction on all exposed surfaces in the tank & sump space ensures easy maintenance for the life of the pump
    • Built upon the same field proven Red Jacket STP platform with identical sizes. Fully compatible with fielded “The Red Jacket” STP models for easy upgrade.

Visit The Product Page                       Download The Data Sheet

 

 

Red Jacket Sump-Dri Dessicant System

Corrosion Protection for Submersible Turbine Pump Sump Space

The new Sump-Dri Desiccant System is an instant in-sump solution for reducing the corrosive effects of moisture in sumps. Designed to maintain moisture- and acetic acid-free conditions in a sump space, preventing deterioration of metal surfaces, including contractor’s boxes, pumps, and conduit.

Key Features:

  • Ensures the safety and serviceability of your sump-space equipment
  • Specifically formulated to protect equipment in the STP sump from corrosive conditions
    •     Reduces relative humidity
      •     Neutralizes corrosive acetic acid vapors
  • Use alone or in conjunction with protective coatings for added insurance

Part Number: Sump-Dri Kit 330020-843
Collection Capacity: 1 gallon
Operating Temperature: -4° to 150°F [-20° to 65°C]
Size: 15.5″ x 15.5″ x 3.25″
Unsaturated Weight: 5.5 lbs
Saturated Weight: 14 lb
Desiccant: Formulated specifically to protect against corrosive acetic acid produced by biodegradation
Brine:

  • Absorbed moisture & neutralized acetic acid vapors create a brine solution
  • Brine solution is collected & trapped in the reservoir to limit re-evaporation

Disposal:

  • Made from non-toxic and recyclable materials
  • Remove end cap and pour brine solution into sump liquid waste stream

Installation/Mounting:

  • Included mounting hardware allows Sump-Dri to be hung from STP, or other existing equipment in sump
  • Carabiner can be used to clip Sump-Dri to STP eyelet other sturdy equipment in the sump. Strap can also be unclipped from Sump-Dri, looped around equipment, then re-attached to the unit
  • Sump-Dri should be positioned as high as possible in the sump. Height can be adjusted using plastic slide on strap

Sump Requirements: For maximum effectiveness, sump should be tight and free from standing water
Desiccant Life/Change Interval:

  • Sump-Dri expected to last 3-6 months under typical conditions
  • Sump-Dri will absorb differently based on humidity and temperature conditions and should be changed when desiccant in upper chamber has completely depleted

Shelf Life: 3 years under typical conditions when left in sealed barrier bag

Visit The Product Page               Download the Sump-Dri Desiccant System Data Sheet

If you would like to learn more or get a quote for the Red Armor STP and/or the Sump-Dri Desiccant System, call us at 1.800.451.4021.

The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Red Jacket – MAXXUM ‘PIGTAIL’ PART NUMBER & COLOR CHANGE

RedJacket_logo

The Red Jacket Maxxum ‘Pigtail’ connector will transition to a new UL approved connector with a black grommet. This connector change will phase in over the summer. No other characteristics of this part are changing and either connector can be used with confidence on any 6” Maxxum/Big Flo/High Capacity job site.

RJ_MaxxumPT

Please refer to Manual part nos. 577014-089 or D051-301 for full details concerning installation, operation and maintenance requirements.
As part of our continued roll out of Maxxum improvements in 2014 and 2015, the following part number changes apply. Customer Service will work with you to provide uninterrupted access to parts as we complete the transition from the old to the new part numbers.

RJ_MaxxumPN

As always, feel free to contact us at 1.800.451.4021 with any questions.


We appreciate your business and thank you for your continued support!

JWK Logo