All You Need to Know About Automated Fuel Dispensers

Years ago, attendants at a gas station used to fill up your tank, but in most states, these services have ended as self-service pumps have become more popular. Not only is this pump style convenient and easy to use, but it also allows you to enter and exit the gas station quickly.

Self-service pumps commonly have automated fuel dispensers that allow customers to pump gas and pay via card. This blog will discuss automated fuel dispensers in detail.   

Automated Fuel Dispenser: An Overview

Automated fuel dispensers let customers pump their gas and pay for it. As you swipe a credit card at a gas station featuring an AFD, an authorization request is sent to your bank. That’s when the system requires your cardholder verification information. This may either be a ZIP or PIN code.

Once the authorization is complete, you can choose your fuel grade and pump your gas without the assistance of an attendant. After the completion of the transaction, billing information will be transmitted, and your account will be billed. Customers can either pay through debit/credit card or cash.  

Features of Auto Fuel Dispensers

With automated fuel dispensers, pumps don’t require attendants anymore. AFDs ensure more customers pump gas quickly without the help of several employees. This means reduced wait time for customers and increased capacity for fuel stations.

Most AFDs include cloud-based fuel management systems that use the latest technology to give up-to-date information regarding fuel usage. The system can tell the amount of fuel sold and provide information about fuel loss.

Watch Out for Fraud

Fraud is one of the biggest concerns with automated fuel dispensers. Since AFDs don’t require an active attendant, there’s a higher risk of fraud. For instance, a customer may fraudulently request a refund on their gas purchase—chargeback fraud. Based on some estimates, almost 95% of all chargebacks are fraudulent.

Cloud-based fuel management system

Gas Station and Petroleum Equipment

John W. Kennedy Company is a one-stop gas station and petroleum equipment supplier in Providence. Our vast range of products includes everything from entry fittings, power management systems, POS systems, gasoline equipment, and much more!

Get in touch with us for more information, or check out our valuable resources here.

OMNTEC Authorized Service Contractors Training 05/09/2022 11am EST








Omntec Logo

Join Omntec For Their Next Remote Web-Based Training

May 9, 2022 @ 11AM EST

REGISTRATION DEADLINE: May 2nd at 4PM
Don’t hesitate, register today!

CLICK HERE TO REGISTER FOR OMNTEC TRAINING

Omntec Proteus ATGsIf you have not been trained or need recertification on Omntec’s Proteus line, we strongly recommend attending one of their FREE training sessions.

OMNTEC’s FREE ASC training is a web-based course including an exam that can be completed at your own pace. The training presentation is live and hosted through Zoom. The course is roughly 2.5 hours long.

After you register you will receive an email with links to documents you can reference during the training session and the certification.

The Zoom meeting link will be sent out the Friday before the training session. Upon completion of both the training and exam, you will be provided a certificate and a wallet card that will be emailed directly to you.
Omntec Proteus ATG

Omntec logo
You can find Omntec products in our web store
John W Kennedy Company | Omntec SBI
Use our Proteus Shop By Image feature

Feel free to contact us at 1.800.238.1225 or Email Us with any further questions or to place an order!


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Veeder-Root: Technical Support Notification – HydrX™ Installation Update

Preview in new tab

HydrX™ Installation Update

HydrX Installation Requirement

Prior to installing a HydrX Fuel Conditioning System, ensure all hardware is received and on site. Failure to install the system completely can result in diesel fuel releasing into the containment sump and creating a dangerous condition. If you feel you are missing parts or components, contact Veeder-Root Technical Support at +1.800.323.1799, before proceeding with the system installation.

IMPORTANT: Only Veeder-Root HydrX Certified Technicians are authorized to install this system.

If you have not already, enroll in the web-based Veeder-Root HydrX Install and Service Course. This 1-hour course prepares Veeder-Root ATG Certified Technicians to install and service the HydrX Fuel Conditioning System. Users will become familiarized with all primary components of the HydrX system, including: the Fuel Conditioner, Water Intake Device, Guide Tube, and Fuel Conditioning Controller.


Quick Links for Self-Enrollment

NOTE: You must sign up with Gilbarco Veeder-Root in order to enroll in the online training if you haven’t done so previously!

Course Link Class Link

Click here to learn more about HydrX System Requirements


Download the complete TSN here!
Veeder-Root TSN HydrX Installation


LOOKING FOR VEEDER-ROOT SYSTEMS & PARTS?

Well look no further – click on the Veeder-Root logo below to visit our web store, where we have hundreds of the most popular Veeder-Root items ready to buy in our webstore and if you can’t find it there, please contact us!
Veeder-Root logo


If you have any questions about HydrX or would like to receive a quote for HydrX or any other Veeder-Root system and/or parts , please feel free to contact us at 1-800-451-4021 or Email Us !!


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Veeder-Root: Technical Support Notification TLS-450PLUS & TLS4 Series – iButton Obsolescence








TLS-450PLUS & TLS4 Series
iButton Obsolescence

Overview

As of March 2022, iButtons are no longer being used in consoles with software version 10.C or later. The software
features will be stored directly on the CPU Boards. The CPU Boards will still have a socket for the iButton but will have a “NOT USED” decal included (see image below).
IMPORTANT: The iButton is still needed for consoles with software version 10.B or prior.
Veeder-Root TLS iButton

All TLS-450PLUS & TLS4 Series Consoles

CPU Board Replacement
✏ Software version 10.C or later will no longer use the iButton.
✏ Software version 10.B or prior will continue to use the iButton and it must be moved to the new CPU.


iButton Replacement
Replacement iButtons are no longer available.
✏ TLS-450PLUS consoles with defective iButtons will require the new CPU and software version 10.C or later.
✏ TLS4 Series consoles with defective iButtons do not require replacing the CPU but must be upgraded to software version 10.C or later.


Migrating a TLS-450 to a TLS-450PLUS Console

Migration kits are no longer available for purchase. Last time buy was December 31, 2021. However, if you have a migration kit, follow these steps to migrate a TLS-450 to a TLS-450PLUS console.

1. Create a backup of the TLS-450 using the thumb drive provided in the kit.
2. Install the new CPU and SD card.

IMPORTANT: Do not move iButton to the new CPU.

3. Restore the TLS-450 back-up into the TLS-450PLUS.

Note: In some circumstances, a “Media Access Error” may occur but will clear once the database restore is complete.

Veeder-Root TLS450 to TLS450PLUS


Download the complete TSN here!Veeder-Root TLS-450PLUS & TLS4 Series – iButton Obsolescence


LOOKING FOR VEEDER-ROOT SYSTEMS & PARTS?

Well look no further – click on the Veeder-Root logo below to visit our web store, where we have hundreds of the most popular Veeder-Root items ready to buy in our webstore and if you can’t find it there, please contact us!
Veeder-Root logo


If you have any questions about TLS450 or would like to receive a quote for TLS450 Series or any other Veeder-Root system and/or parts , please feel free to contact us at 1-800-451-4021 or Email Us !!


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Veeder-Root: Technical Support Notification TLS-450PLUS – Divider Plates








TLS-450PLUS – Divider Plates

Introduction

The TLS-450PLUS console must be installed per the TLS-450PLUS Site Prep and Installation Manual (577014-073) and the UL/cUL Control Drawing – TLS-450/8600 Consoles (331940-008). The console may not be modified in any way.  This includes drilling holes, cutting the metal and plastic walls or removing the divider plates located in the module bay.  Removing or modifying the divider plates can lead to the product or installation not being compliant with UL/cUL requirements. All three divider plates must be left in place in-between any of the four slots in the TLS-450PLUS console or TLS-XB Expansion Box.

IMPORTANT: Removing the divider plates can lead to electrical noise interference issues and violates UL/cUL and other licensing bodies.

Designated knockouts are the only approved wiring openings. As needed, knockouts can be removed to allow rigid
conduit to be connected to the console. Any unused positions where knockouts have been removed must be properly sealed, per the latest National Electric Code.


Installation Review

This example shows a clean installation.
TLS450Plus Divider Plates CORRECT Install
All wires exit the console and immediately enter a rigid conduit (not shown).

✅ In addition, the console has not been altered in any way; unused knock-outs have been left in place and the divider plates have not been removed (each module is physically separated with a metal plate).


This example shows an incorrect installation.

Veeder-Root TLS450PLUS Divider Plates INCORRECT Install
❌ The divider plate was removed between the two USM modules, in slots 2 and 3. This is against Veeder-Root’s installation requirements and violates the UL/cUL and other licensing bodies. The divider plate must remain in place and cannot be modified.

❌ All wires must be run through rigid conduit and can only be used in the module slot that the conduit is connected to.

Download the complete TSN here!
Veeder-Root TLS450PLUS Divider Plate Tech Notification


LOOKING FOR VEEDER-ROOT SYSTEMS & PARTS?

Well look no further – click on the Veeder-Root logo below to visit our web store, where we have hundreds of the most popular Veeder-Root items ready to buy in our webstore and if you can’t find it there, please contact us!
Veeder-Root logo


If you have any questions about TLS450 or would like to receive a quote for TLS450 Series or any other Veeder-Root system and/or parts , please feel free to contact us at 1-800-451-4021 or Email Us !!


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

OMNTEC Authorized Service Contractors Training 03/14/2022 11am EST








Omntec Logo

Join Omntec For Their Next Remote Web-Based Training

March 14, 2022 @ 11AM EST

REGISTRATION DEADLINE: March 10th at 4PM
Don’t hesitate, register today!

CLICK HERE TO REGISTER FOR OMNTEC TRAINING

Omntec Proteus ATGsIf you have not been trained or need recertification on Omntec’s Proteus line, we strongly recommend attending one of their FREE training sessions.

OMNTEC’s FREE ASC training is a web-based course including an exam that can be completed at your own pace. The training presentation is live and hosted through Zoom. The course is roughly 2.5 hours long.

After you register you will receive an email with links to documents you can reference during the training session and the certification.

The Zoom meeting link will be sent out the Friday before the training session. Upon completion of both the training and exam, you will be provided a certificate and a wallet card that will be emailed directly to you.
Omntec Proteus ATG

Omntec logo
You can find Omntec products in our web store
John W Kennedy Company | Omntec SBI
Use our Proteus Shop By Image feature

Feel free to contact us at 1.800.238.1225 or Email Us with any further questions or to place an order!


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Veeder-Root: TLS4 Series Security Settings








TLS4 Series

Technical Support Notification

TLS4 Series Security Settings

Overview

The TLS4 Series consoles come with security features allowing for greater protection and control of access to the Automatic Tank Gauge. Features such as configurable user access and segmented network ports help ensure both network and front-panel security.

This update covers:

  • User and Roles Admin
    • Create User Accounts
    • Custom Roles
  • System Security
    • Front Panel Security
    • Serial Command Port (TCP/IP Interface)
    • SSH Port
    • Serial Command Over SSH
    • HTTPS Port
    • User Admin Via Web
  • Router and Network Switch

User & Roles Admin

Create User Accounts & Custom RolesCreate User Accounts

All TLS4 Series consoles come preconfigured with three roles: Administrator, Operator and Regulator. Additional custom roles can be programmed.

Menu –> System Administration –> Roles Admin

Administrator: This role gives full access to the console – including the ability to create new roles and users.

Operator: This role allows the user to view and generate reports and perform certain manual functions, such as starting a manual line or tank test.

Regulator: This role allows the user to print and view console reports.

Note: Users assigned to the Regulator role cannot be deleted.

To add a Custom role, select Actions –> Add New Role

The Custom role allows each individual screen to be viewable, editable or not accessible. For example, in Setup under the Automatic Events section, each option can be customized:

Veeder-Root strongly recommends creating an Administrator account with a unique password. This will disable the default username and password.

Note: When using the Plus View or Remote View apps, the same login credentials are used.


Security

System SecuritySecurity Settings

The TLS4 Series consoles have optional security features to enhance protection in addition to front panel security that requires a username and password, when enabled.

Front Panel Security: When disabled, all users can access all screens with no password required. When enabled, users must login with a password to gain access to the screens they’re allowed to view.

Serial Command Port (TCP/IP Interface): When disabled, the console will not accept any serial commands sent through a telnet session.

Note: This will not block all traffic on the TCP/IP port. It will only block serial commands.

SSH Port: When disabled, all traffic on the SSH port will be blocked.

Serial Command Over SSH: For the SSH Public Keys feature to work, this port and the SSH port must be enabled. By default, this port is disabled.

HTTPS Port (Web Access): When disabled, all traffic on the HTTPS port will be blocked. This will prevent access to the web portal, and the Plus View and Remote View apps.

User Admin via Web: When disabled, the System Administration screens will be blocked from the web portal – access to these two screens will only be available on the console’s front panel.

Router or Network Switch

Most routers or network switches have additional features allowing ports to be enabled or disabled. Contact device manufacturers or internet service providers (ISPs) for more information.


Download the TLS4 TSN HereVeeder-Root TLS4 TSN


LOOKING FOR VEEDER-ROOT SYSTEMS & PARTS?

Well look no further – click on the Veeder-Root logo below to visit our web store, where we have hundreds of the most popular Veeder-Root items ready to buy in our webstore and if you can’t find it there, please contact us!
Veeder-Root logo


If you have any questions about TLS4 Series or would like to receive a quote for TLS4 Series or any other Veeder-Root system and/or parts , please feel free to contact us at 1-800-451-4021 or Email Us with any further questions or inquiries.


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Veeder Root: HYDRX Fuel Conditioning System









LOOKING FOR VEEDER-ROOT SYSTEMS & PARTS?

Well look no further – click on the Veeder-Root logo below to visit our web store, where we have hundreds of the most popular Veeder-Root items ready to buy in our webstore and if you can’t find it there, please contact us!
Veeder-Root logo


If you have any questions about HydrX or would like to receive a quote for HydrX or any other Veeder-Root system and/or parts , please feel free to contact us at 1-800-451-4021 or Email Us with any further questions or inquiries.


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Software Release Version 10.B








Veeder-Root TLS-450PLUSSoftware Release Version 10.B
TLS-450PLUS and TLS4 Series Consoles

Purpose

This document announces the release of version 10.B software for the TLS-450PLUS and TLS4 series consoles.

Performance Enhancements

Intelligent Pump Control Reports
• Advanced Diagnostics Reporting for Intelligent Pump Control (IPC) for Red Jacket STPs. IPC collects statistical data from pump controllers that includes daily run time, start count, number of help requests, faults, fault counts, time in a fault condition, min/max/average (running) voltage and amperage.

Ongoing Improvements
• Version 10.B includes miscellaneous bug fixes and updates.

Software Upgrade Kit – TLS-450PLUS, TLS4 Series Consoles

Software upgrades are always free to download on the Veeder-Root website at veeder.com/us/software-downloads.

Software upgrades can also be ordered on a USB Flash drive at no charge by ordering the software kit part number
in the table below:

Part Number Description List Price
0330020744 TLS450PLUS, TLS4 Series Operating Software Upgrade No Charge

Documentation

Manual information is available at veeder.com/us/technical-document-library.


LOOKING FOR VEEDER-ROOT SYSTEMS & PARTS?

Well look no further – click on the Veeder-Root logo below to visit our web store, where we have hundreds of the most popular Veeder-Root items ready to buy in our webstore and if you can’t find it there, please contact us!
Veeder-Root logo


If you have any questions about this software release notification or would like to receive a quote for Veeder-Root systems and/or parts , please feel free to contact us at 1-800-451-4021 or Email Us with any further questions or inquiries.


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Pneumercator January 2022 Technical Certification Training Webinar Invitation








2-Day Online Technical Certification Training

When:  January 11 – 12,2022 (2-day online course)
Time:  9AM to 4:30PM Eastern (8AM to 3:30PM Central, 7AM to 2:30PM Mountain, 6AM to 1:30PM Pacific)

Cost: $275.00 per technician. DO NOT EMAIL CREDIT CARD INFO.

To Register: Call 1.631.293.8450 or email robyn@pneumercator.comDO NOT EMAIL CREDIT CARD INFO.

NOTE: You will be provided with the webinar link once you have registered. Certification is valid for 2 years


Pneumercator TMS4000Course Overview: This class offers technicians the opportunity to obtain or renew factory certification necessary to perform installation, startup, repair, and maintenance of the select Pneumercator products listed below.


Recommended Experience/Education: All attendees should have some prior experience with the installation and
maintenance of electronic tank gauging and leak detection systems, including general knowledge of NEC/NFPA electrical code requirements, and more specifically, hazardous location classified installation and wiring requirements and safety procedures.

Pneumercator TMS2000

Required Materials: A computer with internet access. Webcam optional. Dial up voice support provided via telephone number upon signing into webinar. Groups may share a computer but a larger screen (i.e. projector, large TV, etc.) is recommended.

Materials Provided:
Training Presentation via internet link.

TMS Communicator via internet link.

Certification: Renewal required every 2 years.


Pneumercator LC1000AProducts Covered:

  • LC1000-A Series Non-Discriminating Leak and/or Pt. Level Sensing system.
  • LC2000 Series Discriminating/Non- Discriminating Leak/Pt. Level Sensing system.
  • PC1000 Series pump controller.
  • TMS Series Automatic Tank Management Systems.
      • TMS3000: Multi-Tank Gauging System, 12 Tanks and 40 Leak/Pt. Level Sensors.
      • TMS2000: Two Tank Gauging System, 8 Leak/Pt. Level Sensors.
      • TMS2000W (Wireless): Multi-Tank Gauging System, 12 Tanks and 40 Leak/Pt. Level Sensors.
      • TMS1000: Single-Tank Gauging System, Non-Hazardous Applications, 4 Leak/Pt. Level Sensors.
      • TMS2000A1x: 4-20 mA Input Tank Gauging System, 4 Tanks and 4 Leak/Pt. Level Sensors.

    Pneumercator Probe

    • TMS2000A2x: Resistive Input Tank Gauging System, 4 Tanks and 4 Leak/Pt. Level Sensors.
    • TMS4000: Multi-Tank Gauging System w/Touch Screen, 48 Tanks and 48 Leak/Pt. Level Sensors.
    • TMS4000W (Wireless): Multi-Tank Gauging Sys. w/Touch Screen, 32 Tanks and 128 Leak/Pt. Level Sensors. 
  • Magnetostrictive Probes
  • Sensors
    • Point Level Sensors
      • LS600 Series (includes LS600, LS600W, LS600M, LS600F4, and LS600X)
    • Leak Sensors
      • LS600LD
      • LS610
      • RSU800
      • Pneumercator ES825 SensorES825 (Non-Discriminating and Discriminating)
      • HS100ND
      • HS100D
    • Line Leak Sensors
      • LLP203
  • TMS Communicator
    • TMSComm
    • Autopolling
    • TMS Network Configuration
  • Special Applications using flexible probes: Bulk Storage, Low Ceiling clearance, Chemicals.


See the Pneumercator Technical Certification Training Class Invitation here.


Looking for Pneumercator systems and parts? Pneumercator Liquid Level Control SystemsCheck out our web store!

And if you can’t find what you are looking for, please call us at 1.800.238.1225 or Email Us with any further questions or to place an order!


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo