Sump Repair is a SNAP with Icon

Save time and money replacing conduit fittings in secondary sumps, chambers, and containers.
Icon SnapLock

The all new Icon SplitRepair SnapLock Fitting makes installation a SNAP inside secondary containment sumps. Immediately available for conduit fitting repairs. No need to disconnect pipe. Installation is as simple as…

BOND • SNAP • BOLT • CLAMP

Every Icon SplitRepair SnapLock Conduit Fitting is made with PROTEX and comes with the Icon Lifetime Warranty.

WATCH SNAPLOCK IN ACTION


Be sure to check out the ICON booth and register for their repair certification at our upcoming 2023 Petroleum Equipment Trade Show!!
REGISTER ONLINE TODAY!!
2023 JWK Trade Show

WHEN:

Wednesday, March 29th: 9AM – 4:30PM
Cocktails & Hors d’oeuvres 4:00PM – 7:30PM (Open Bar)

Thursday, March 30th: 9:00AM – 12:00PM

WHERE:

Crowne Plaza Warwick
801 Greenwich Avenue
Warwick, RI 02886
401.732.6000
Click here for directions.


Training & Certification Seminar Schedule
Wednesday March 29th
FFS APT 8:00 – 9:00am APT Piping Re-Certification
9:15 – 10:15am OPW Underground Piping Re-Certification
Containment Solutions 10:30 – 11:30am CSI UST Installation Re-Certification
11:45am – 12:45pm Emco Wheaton EVR Re-Certification
1:00 – 2:30pm Icon Sump & Fitting Repair Certification

We are back once again with the most anticipated petroleum equipment trade show with dozens of vendors featuring their latest and greatest product offerings along with training and re-certification seminars. We end the first day with a cocktail hour featuring an open bar, great Hors-d’oeuvres and live entertainment! So don’t miss out!

2023 JWK Trade ShowREGISTER ONLINE TODAY!!


LOOKING FOR ICON FITTINGS & PARTS?

Click on the ICON logo below to visit our web store!
ICON logo


If you have any questions about ICON fittings and/or parts , please feel free to contact us at 1-800-451-4021 or Email Us !!


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Bravo Technical Service Bulletin: Installing New Construction Fittings in Cold Climates

Bravo LogoInstalling New Construction Fittings in Cold Climates

Bulletin Description

• Proper heat curing of epoxy in cold weather conditions.
• In weather conditions below 50°F, heat will be needed to cure epoxy used for the  installations of Bravo full body fittings and test reducers. However, do not heat the fitting above 150°F. Extremely high temps can damage entry fittings and cause test ports to leak.

Do not use NOV heat blankets directly on full body fittings. These greatly exceed the allowable installation temperature and will damage the fitting bodies as well as the test ports.


  • Recommendation: Sustain heat on the entire interior of sump until full cure cycle has been achieved.
  • Warning: Before applying heat make sure LEL ( Lower Explosive Limit) are measured and are at safe levels.
  • Tip: Use an IR temperature gauge to measure surface temperature of sump and fittings.

1) Pre-heat sump and fitting to a maximum of 150°F.
2) Pre-heat Bravo epoxy to a maximum of 100°F.
3) Apply Bravo epoxy to the fitting per installation guide.
4) Sustain temperature of fitting/adhesive following cure charts.
5) Do not move or adjust sumps or fittings during cure cycle.
6) Make sure the adhesive is fully cured before conducting a testing following epoxy manufacturers’ guidelines.


Click here to download the Bravo Technical Service Bulletin
Bravo Fitting Installation Technical Service Bulletin



You can also check out
Bravo YouTube Channelfor more product installation and preparation videos



If you have any questions , please feel free to contact us at 1.800.451.4021 or Email Us !!


The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

Leak Issues? Icon Has Your Solution!

Discover the world’s leading secondary containment repair solutions at Icon Containment Solutions

Icon’s SplitRepair Fittings are designed to be the most simple approach to any configuration of equipment for faster installations, and we have solutions for any combination of sump type, entry/test fittings, and piping (offset or angled pipe).

Icon SPlitRepair Fittings

Sump leak repair vs equipment replacement provides obvious financial and operational advantages to the UST system owner and can be very profitable for the installing contractor. Icon’s entire mission is to help the installer be profitable and still provide significant savings to the owner.

Without a doubt, the conditions for sump repair can be challenging as access is often very limiting. When the sump is repairable, it can be completed successfully and efficiently with the correct applications and support.

GO WITH THE EXPERTS

Icon is exclusively focused on Sump Leak Repair Solutions. Icon’s expertise and range of solutions for any configuration of equipment is unmatched. Use Icon as a resource to develop a more profitable repair business.

Iconfitting 1 Iconfitting 2

SIMPLE

Less installation time in the sump with more reasonable workmanship requirements, and the lowest net cost to completion

PROVEN

Icon direct replacement fitting designs and materials conform to EPA recognized Repair Standard (NLPA/KWA Standard 823) compatibility requirements

PERMANENT

Solutions backed by the Lifetime Warranty on all fittings installed by an Icon Certified Installer

SERVICE

Icon’s #1 priority with Icon direct and ongoing training and technical support for the installer – from initial site survey through testing after successful installation. Most fitting orders are shipped the same or next day from receipt of the order!

Icon fitting 3 Icon fitting 4

Icon PROTEX Flexible Compression-Seal Repair Fittings have never shown any degradation of material through all independent testing and field application. And remember, PROTEX repair fittings can be installed in any ambient conditions and wet environments.


BECOME A SUMP SURVEY PRO

Icon Sump Survey Pro

Icon provides excellent support and training for any individual responsible for answering the questions above. From training those tasked with doing sump surveys, providing parts specifications for repair projects, to training repair product installers, and supporting any personnel involved in the project from start to finish. Contact us about how we can support you and your organization in this opportunity.

Additionally, there is a new Nationally Recognized Standard (EPA recognized) for sump repair and maintenance available to the industry in NLPA/KWA 823.

Site Survey Tips for Repair Evaluation and Parts Specification Support

Format

Icon does not require any specific format for information to be submitted for a parts specification service from our technical support team.  We have supplied downloadable versions of the Sump Survey for your convenience. The form will assist you in organizing the details needed to provide the service. As always, if you need help or have any questions regarding the Sump Survey, please don’t hesitate to contact us.

Site Survey Suggestions & Tips Site Survey Form

Sending to JWK

Simply email this completed form (or send the same information otherwise) via email to RoyO@jwkemail.com or Fax to 401.434.0630.

Leave the rest to us

Above all, we seek your satisfaction. We’ll respond shortly with a list of the exact recommended parts, materials, and supporting documentation for your specific sump leak repair project.

*PREVIEW OF SUMP SURVEYIcon Sump Survey Worksheet


Protex

Icon PROTEX Flexible Compression-Seal Repair Fittings have never shown any degradation of material through all independent testing and field application. Discover all of the advantages of PROTEX today!

WHY PROTEX?


ICON Lifetime Warranty IconProtex IconQualityAssured
Lifetime Warranty

Every Icon fitting is backed by the Life of Sump Warranty.

PROTEX

Made with PROTEX. Choose fitings designed to last.

Tested and Approved

Independently tested to exceed industry standards

LEARN MORE LEARN MORE LEARN MORE

Feel free to call us at 1.800.451.4021 or email us using the link below to
LEARN MORE & GET A FREE QUOTE

The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo

S. Bravo Systems, Inc. Launches Bravo Solution Center

Bravo LogoS. Bravo Systems, Inc. is pleased to announce the launch of their new Bravo Solution Center.Bravo Products - Problem Solved!

Over the past year plus, Bravo has been on a tear improving and expanding every aspect of their business. 

So keeping inline with their goals, contractors and installers now have the ability to call, email and most importantly, text images to the Bravo home office. Based on Bravo’s beta testing of their new Solution Center, the feedback has been extremely positive and being well received by those in the field already.  We are encouraging everyone to take advantage of this resource and support as well as the technology that now allows for live footage and photos to be taken at the job site and immediately sent in to the Bravo Solution Center.

The Solution Center is led by Keith Pearson with Don Mukai serving as back-up when needed. Bravo is committed to responding to all incoming inquiries and requests within 3 hours.

EMAIL:                             bsc@sbravo.com or kpearson@sbravo.com

TEXT OR CALL:         1.323.541.3852

HOURS:                           Monday – Friday: 10:00am – 7:00pm EST  (7:00am – 4:00pm PST)


Cumberland Farms & Bravo

The John W. Kennedy Company appreciates your business and continued support!

JWK USA Logo